Emergency Boiler Repair in Sidcup (DA14)
A condensing boiler makes water as it runs. Where no drain sits below it, a small pump lifts the water away, and if the pump stops, the boiler can too.
Call any time, day or night
07546 185778Covering Sidcup, Foots Cray, North Cray, Longlands, Ruxley and part of Albany Park.
Gas work is carried out by Gas Safe registered engineers we work with. They show you their Gas Safe ID card, and any certificate for the work comes from them.
More than a third of DA14 households live in purpose-built flats, 3,568 of them or 36.4% in the 2021 Census, the third highest share of the 18 districts. The buildings are mostly older than the boilers inside them. The Valuation Office’s 2026 count of homes by the decade they were built finds only about one home in eight built after 1999, and since April 2005 the Building Regulations have required a replacement gas or oil boiler to be a condensing one in all but exceptional cases. So in most DA14 homes with a condensing boiler, flats included, the boiler arrived long after the building did, and its drain had to be found in a layout never planned for one.
Where no drain could be reached, a pump went in.
Condensate pumps in boiler cupboards
A condensing boiler produces water as it runs, and the water has to go somewhere. The industry’s guidance is for it to fall by gravity to a drain inside the home: an internal soil stack by preference, otherwise a kitchen, bathroom or shower waste. In a flat that is not always possible. The drain may be higher than the boiler, there may be a doorway between the boiler cupboard and the nearest waste, or the pipe would have to run a very long way, and in each of those cases the guidance says a condensate pump should be used. A pump like the Grundfos Conlift is a small separate unit with its own power lead. Grundfos designs it for no more than 60 starts an hour. The boiler’s water runs down into its tank, a float switch starts the pump when the level reaches one point and stops it when the level falls to another, and the water is pushed along a thin hose to the drain. The Conlift also has an overflow switch that can be connected to the boiler and set to stop it if the tank reaches its alarm level. Everything turns on that word can. If the switch is wired in, a pump that fails stops the boiler and the house goes cold. If it is not, the boiler carries on making water for a tank that cannot empty. There is a thermal switch as well, which stops the motor if it is overloaded and restarts it once it has cooled.
Not to be confused with a frozen condensate pipe outside.
Start with what you can see without opening anything. Is the boiler showing a fault, and is the pump making an alarm? Is the pump’s power on at its plug or switch? Grundfos’s fault table gives four reasons for a pump that will not run: no power, a blown fuse, a damaged cable, or the thermal switch having tripped. Only the first is yours to put right. The rest are inside the unit, and Grundfos says the power must be off before any work on it. Do not tip the tank or pour anything into it either: Grundfos describes boiler condensate as very aggressive.
We start with the pump, not the boiler. Power and its fuse, then the float, then the hose and the non-return valve, because Grundfos lists a squeezed or broken outlet hose and a non-return valve that will not open among the causes of a pump that runs without shifting water. The tank gets cleaned if it needs it, and we find out whether the overflow switch is wired to the boiler, so you know which kind of failure to expect next time. Then the boiler is reset the way its own instructions say. Whether that is the end of it depends on the pump: some come back with a clean, some need replacing, and you hear which before anything is ordered.
The pump failing is no reason to scrap the boiler, but if yours is due anyway, we also arrange boiler installations, and a replacement is when to ask whether a new one needs a pump at all.
Boiler questions in Sidcup
Our Sidcup flat was built in the sixties. Why would its boiler need a pump?
Because the flat is older than the boiler. When it was built, boilers made no water that needed draining. A condensing one does, and where its cupboard sits below the nearest waste, or across a doorway from it, the industry’s guidance is a pump rather than a pipe carried round the door frame.
The small box under the boiler is beeping. What should I do?
Switch the boiler off and leave the pump alone. On a Grundfos pump an alarm means condensate is not being pumped out of the tank. Switching off stops more arriving.
The pump clicks on and off every few minutes, even with the heating off. Why?
Grundfos puts frequent starts and stops down to a non-return valve that is not closing, so water runs back into the tank, or to too much water coming in. Cleaning it is a power-off job.
Does a condensate pump need any looking after?
Grundfos recommends checking how its Conlift runs, and its pipe connections, at least once a year, and cleaning the tank if necessary. It sits out of sight and is easily forgotten.
Google Reviews
4.8198 reviews
Speedy, efficient and nice chap to deal with. We had a leak from above and he was able to see yo and get fixed imminently. We live in Penge and was able to serve the local area
Excellent service from start to finish. We had an emergency situation after 7 pm, and they responded promptly and resolved the issue quickly and professionally. Their efficiency and reliability were greatly appreciated. I would not hesitate to use their services again and highly recommend them to others.
Really quick response time, they came next day. Lovely blokes and got the required work done promptly, very happy with service received. Will definitely use London City Plumbers again!
I would like thank Mr. Ferrell from London City Plumber. Very good and timely advise, really appreciate it. He is very helpful, and guided me with the options available. I would definitely recommend him.
Excellent service. We had a blockage in our main pipe which other plumbers failed to identify. We called Farrell who arrived within an hour the same evening, immediately identified the blockage and removed it, giving us our bathroom back. Highly recommended and will definitely call again for future issues.
Google decides which reviews surface here, not us. Read all 198 on Google
More for DA14
Plumbers & electricians in Sidcup
Everything else we do in DA14, from leaks and drains to electrics, is on the district page. Boiler work in general is on Boiler Repairs in London and Kent.
Next door to DA14
Ring us about a boiler in Sidcup
Tell us the postcode, the make of boiler and what it is doing, and you will get a straight answer before anything is booked.
Call any time, day or night
07546 185778