Emergency Boiler Repair in Belvedere (DA17)

A bigger share of DA17 households heat with electricity alone than in any other DA district, and when that electricity runs a boiler on radiators, a breakdown can sit in the pipes or in the cable.

Call any time, day or night

07546 185778

Covering Belvedere, Upper Belvedere, Lessness Heath, West Heath and part of Abbey Wood.

Gas work is carried out by Gas Safe registered engineers we work with. They show you their Gas Safe ID card, and any certificate for the work comes from them.

The 2021 Census counts 1,168 households in DA17 with electric-only central heating, 15.6% of the district, the highest share of the 18 and well above the 8.7% for England. Its option read "Electric (including storage heaters)", so the figure does not split storage heaters from electric boilers. This page is about the boiler: a box on the wall with no flue, no gas pipe and nothing to relight, heating water that a pump sends round radiators. About a third of households, 32.6%, live in purpose-built flats, and needing no flue is one reason electric boilers turn up in them.

Nothing burns in one, but plenty can trip.

Electric boilers on wet radiators

Inside the case there is no burner and no flame. Heatrae Sadia’s Amptec manual describes the water being heated as it passes over electric immersion elements in a chamber, and something has to switch those elements on and off to hold the temperature: a contactor on EHC’s Slimjim, solid-state switching on the Amptec, triac boards on Strom’s boilers. Round that sit the protections, and each one is a way for the heating to stop. A thermal cut-out cuts the power if the water reaches about 100°C, and on the Slimjim and Fusion Comet a tripped one leaves the front panel dark, which looks like a lost supply. On the Slimjim, EHC says a service engineer has to reset it and then find out why it went. A flow or water sensor keeps the elements off when water is not moving through the boiler, or not there at all, so air in the system, a pump that has stopped or valves left shut will stop the heat, and the Fusion Comet flashes its pump light to say so. EHC’s fault table for the Fusion Comet traces a boiler that runs but only partly heats to one or more elements getting no voltage from the power board. And in a home with an electric shower, EHC recommends a shower sensor and Heatrae Sadia describes a relay, each of which switches the boiler off while the shower runs, so heating that stops while someone showers and comes back afterwards is doing what it was wired to do.

That is why this is only partly a plumber’s job. An electric boiler runs on a heavy circuit of its own: EHC’s table for the 9kW Fusion Comet gives a load current of 37.5 amps on 50 amp protection, and for the 14.4kW model 60 amps on 80. EHC calls for a 30mA double-pole RCD, an isolator beside the boiler when it is not by the meter, and cable sized by calculation to BS 7671. Strom adds that its boilers draw more current as the voltage rises, and can leak current to earth by design, so an RCD that keeps tripping may mean the boiler needs one of its own.

Heatrae Sadia says plainly: loose connections will cause a fire.

What you can check is all on the outside. Is the display lit, and is it showing a code or a flashing light? Is the boiler’s breaker at the board on, and the isolator beside the boiler? Is the programmer or room thermostat asking for heat? Is anyone using the electric shower? If a breaker has tripped, putting it back once is reasonable. If it goes again, leave it off: Electrical Safety First says an RCD that keeps tripping likely means a fault in an appliance or the wiring, and Strom lists loose connections and the wrong cable or breaker among the causes of nuisance tripping on its boilers.

Leave the casing on: Strom’s cut-out resets are inside it.

We test both halves. On the electrical side that means the supply at the boiler’s terminals, every connection, the switching and each element: the Amptec manual gives an element’s resistance as about 19 ohms on most models and its insulation to the case as more than 2 megohms. On the water side it means flow, air, the pump, and any sign of water getting into the case, which Heatrae Sadia, EHC and Strom all warn about. Being plumbers and electricians, we can follow a fault across that line without handing it on. Then it depends on the model. A dead power board or sensor on the Fusion Comet is a replacement part, but Heatrae Sadia says an Amptec whose elements test open circuit, or short to the case, must be replaced.

If the elements on yours have gone that way, we also arrange boiler installations, and the first question then is what the supply and the home can take.

A grey Joule hot water cylinder in a cupboard, with the immersion element under a white cover near the bottom and its white cable, and copper pipework and a red capped valve to the left
An immersion element under its white cover.An electric boiler heats radiator water over elements of this kind.

Boiler questions in Belvedere

Belvedere tops the 18 districts for electric-only heating. Is mine an electric boiler?

The Census figure cannot tell you: it counts storage heaters too. Radiators with pipes, fed by a boiler with no flue and no gas pipe, mean an electric boiler on a wet system. Heaters with no pipes are a different system with its own page.

The heating goes off whenever someone has a shower. Is the boiler faulty?

Probably not, if the shower is electric. EHC and Heatrae Sadia both describe an interlock that switches the boiler off while the shower runs. If the heating stays off afterwards, the interlock may be stuck.

Can I reset the overheat cut-out myself?

Not the one inside the case. EHC says a service engineer resets the Slimjim’s, and Strom says only an electrician should open its boilers, power isolated first. A cut-out trips for a reason, and the reason is still there.

Everything else came back after a power cut, but the boiler did not. Why?

Check its own breaker and isolator first. If those are on and the panel stays dark, the electronics may have taken the hit: EHC calls the Comet PV sensitive to surges. That needs testing, not resetting.

Google Reviews

4.8198 reviews

Arbi Raia month ago
Speedy, efficient and nice chap to deal with. We had a leak from above and he was able to see yo and get fixed imminently. We live in Penge and was able to serve the local area
M Nova4 months ago
Excellent service from start to finish. We had an emergency situation after 7 pm, and they responded promptly and resolved the issue quickly and professionally. Their efficiency and reliability were greatly appreciated. I would not hesitate to use their services again and highly recommend them to others.
Luke Davies5 months ago
Really quick response time, they came next day. Lovely blokes and got the required work done promptly, very happy with service received. Will definitely use London City Plumbers again!
Kiran6 months ago
I would like thank Mr. Ferrell from London City Plumber. Very good and timely advise, really appreciate it. He is very helpful, and guided me with the options available. I would definitely recommend him.
Leo7 months ago
Excellent service. We had a blockage in our main pipe which other plumbers failed to identify. We called Farrell who arrived within an hour the same evening, immediately identified the blockage and removed it, giving us our bathroom back. Highly recommended and will definitely call again for future issues.

Google decides which reviews surface here, not us. Read all 198 on Google

More for DA17

Plumbers & electricians in Belvedere

Everything else we do in DA17, from leaks and drains to electrics, is on the district page. Boiler work in general is on Boiler Repairs in London and Kent.

Next door to DA17

Ring us about a boiler in Belvedere

Tell us the postcode, the make of boiler and what it is doing, and you will get a straight answer before anything is booked.