Towel rail off the wall, pipes broken

Job Area: Hayes and Keston (BR2)

A square hole cut in a floor beside a tiled wall, the floor covering rolled back, and under it a grey plastic pipe with a white push-fit fitting on its end.
The floor opened by the wall, the pipe and its fitting underneath.

A heated towel rail came away from the wall and broke the two pipes that fed it. The floor opened by the wall, and the pipe underneath with its fitting.

A heated towel rail came off the wall and broke the pipes that fed it, and the leak was under the floor.

What happens when a towel rail falls off the wall?

Its weight lands on the two pipes that feed it, and they bend or snap where they come up through the floor. Heating water then leaks out under the floor covering until the valves are shut or the system is drained, and the pipes have to be reached from below to be joined again.

The photograph is the floor beside the tiled wall once it was opened. The floor covering is rolled back, a square has been cut out by the skirting, and in the gap below is a grey plastic pipe with a white push-fit fitting on its end. A second opening a little further along the wall reached the other pipe the same way.

Why the pipes go

A towel rail hangs on four small brackets, and the two pipes at the bottom are there to carry water, not to hold anything up. When the brackets let go, the whole rail, full of water, drops onto those pipes. They come up through the floor in a short stiff length with a valve on top, so there is no slack in them and nowhere for the movement to go. On this job the copper tails bent over at the floor and the leak started underneath, out of sight, where the copper met the plastic pipe that runs under the floor. That is the awkward part of a job like this. The water is heating water, dark and under pressure while the system is running, and it spreads under the floor covering before any of it shows on top. The first thing is to stop it, by closing the valves if they still turn or by draining the heating down. The second is to find where the pipe has let go, and that means opening the floor at the wall instead of guessing from above. A neat square by the skirting is enough to get a hand and a fitting in, and it can be closed again afterwards.

That is a towel rail that fell off the wall, and a radiator pulled off its brackets does the same thing to its pipes.

Under the floor

Plastic heating pipe is joined with push-fit fittings.

The pipe is cut back to a clean, square end, the fitting is pushed on until it grips, and the joint is pulled to check it has held before the water goes back in.

Back on the wall

The rail goes back on brackets fixed into something solid behind the tiles.

Once it is up, the system is filled, the air is let out of the rail, and the joints under the floor are watched with the heating running before the floor is closed.

The job

A towel rail that has come away is worth a call the same day, even if the leak looks small.

We wrote up a burst pipe repair under the floor and a leak from the flat above before, and our drainage and pipework page covers pipe repairs.

Ring 07546 185778 and say what has come off the wall and whether the valves still turn, and send a photograph if you can.

Common questions

Is the water from a towel rail leak clean?

No. It is heating water, the same water that goes round the radiators, and it is usually dark. It stains flooring and the ceiling below if it is left.

What should I do first?

Close the valve at each end of the rail if they still turn, turn the heating off, and put towels down. Then ring a plumber and say what has come away from the wall.

Why did the pipes break and not just bend?

A towel rail full of water is heavy, and its pipes are short and stiff where they come out of the floor. There is nowhere for them to give, so the joint or the pipe goes.

Does the floor always have to come up?

Only where the pipe has broken below the surface. If it has let go above the floor, at the valve, it can often be put right without lifting anything.

What is a push-fit fitting?

A joint that grips the pipe when it is pushed in, with a seal inside. It joins plastic pipe to plastic or to copper, and it suits a tight space under a floor where there is no room to work a spanner.

How is a towel rail fixed so it stays up?

On brackets screwed into something solid, with fixings that suit the wall behind the tiles. The pipes carry water, not weight, so the brackets have to hold all of it.

A written quote for your job

A clear written quote before any work starts.

Please add your name.
Please add a phone number so we can ring you back.
Please add your postcode so we know where you are.
Please choose what you need.
Or message us on WhatsApp

We'll ring you back to arrange it.

The number to ring

Describe the job on the phone and you will get a straight answer about it, then a price in writing before anything starts.

Call any time, day or night

07546 185778
Call now · 24hr